Dantherm Group
Heylo

Heylo PowerVent 1500 Z1 – axial ventilator

Axial ventilator for hazard zone 3

The combination of ventilator and earthed hose canister is suitable in particular for the ventilation of explosive areas, such as filling stations, fuel depots and filling bodies. In case of repair work in particular on manhole pits, this unit can be used to replace explosive gases by fresh air quickly.

The housing and motor sealing is in keeping with the high protection class IP44 and offers an effective protection against dust and water.

Erection of Compact 1500 Z1 in explosive areas:

  • Installation conditions and different hazardous areas have to be observed.
  • The ventilator must be operated in zone 3 only.
  • The hose of the hose canister be passed through zone 2 into zone 1.
Heylo axial ventilator PV 1500 Z1
Heylo axial ventilator PV 1500 Z1
Zone line up
Zone line up

Key features

  • Ventilator with an air output of 1162m²/h
  • For tank ventilation in potentially explosive areas
  • Installation only in zone 3
  • Strong pressure
  • Easy to set up and quick transportable
  • Light-weight and compact
  • Only approved with Z1 hose canister
  • Hose connection by means of a hose container (optional)

Product specifications

Specifications Units PV 1500 Z1
Air flow
m³/h
1162
Air pressure
Pa
266
Fan type
Axial
Power consumption
kW
0.164
Power supply
V/Hz
230/1ph/50
Rated current
A
0.72
Protection class
IP44
Sound level
dB(A)
68
Hose
Ømm
205
Product size (l x w x h)
mm
380 x 310 x 350
Net weight
kg
8