Dantherm Group
Heylo

Heylo DCS-PV 3000 – dust control system

Dust control system with ventilator

Including: DCD-3.0 (Door base element + 2x PVC foil incl. velcro fastener + transport bag) + Ventilator PowerVent 3000 + dust bag M class + fastening clip + hose (length 7.6m) + hose adapter

The DCS dust protection system is a mobile system consisting of a dust protection door and a mobile fan in the white area. The core piece is the dust protection door DCD - for quick and safe partitioning of doors between the working or dirty area and the white area. By connecting the fan in the white area, a negative pressure is created in the renovation area (black area), which prevents fine dust from spreading into adjacent rooms. As soon as the hose is led through the opening directly to the place where the dust originates in the renovation area, a dust extraction function results.

Clean renovation ensures successful jobs and satisfied customers. Easily transported and quickly installed, the DCS saves you time, money and complications. Time-consuming subsequent cleaning as with water-based systems is not necessary - simply tap out or dispose of the dust bags and filters used.

Heylo dust control system DCS PV 3000
Heylo dust control system DCS PV 3000
Heylo dust control door DCD-3.0
Heylo dust control door DCD-3.0
Heylo ventilator PV 3000
Heylo ventilator PV 3000

Frequently asked questions (FAQs) about dust protection

What is the difference between the white area and the black area?
"Black area" refers to the contaminated (construction site) area. Hazardous substances arising during remediation include asbestos, dusts or mould. "White area" refers to the rooms located outside the contaminated remediation area.

In order to protect the workman and the occupants of the house, the white area is separated from the black area by partitions so that they are not contaminated. Air purifiers are used to ensure occupational safety within the black area. The black/white principle is laid down in corresponding regulations, for example in TRGS 524 (protective measures for activities in contaminated areas) and TRGS 519 (asbestos: demolition, renovation or maintenance work).

How does negative pressure work? Why do I need negative pressure in the work area?
Negative pressure in the work area prevents dust particles from entering adjacent rooms. With negative pressure, the air only flows into the room (work area) from the outside. Fine dust particles that are in the room air of the work area have no chance of getting out of the area.

When do I need a dust control door (DCD), when the dust control wall (HEYWALL)?
The DCD (Dust Control Door) is a door bulkhead that replaces a room door. When in use, the room is separated by a sheet and is easy to walk through. In combination with an air purifier used to maintain negative pressure, the door bulkhead is an effective dust barrier. The hoses of the air purifier are routed through the DCD to the point of dust generation, resulting in extraction at the workplace.

The HEYWALL is a dust barrier that can be used to reduce the size of large rooms or to separate refurbishment areas from others. With easy-to-install telescopic poles, a sheet can be used as a vertical partition to flexibly separate the room. Different construction variants can be realised with the flexible system: L-shape, U-shape, polygon, room divider or airlock. The system can always be reused, supplemented and extended. Special clamps can be used for the contact surfaces on the sides and on the ceiling. Here, too, the dust-tightness increases considerably with the use of an air purifier. If the rooms have been reduced in size with the system, the requirement for the performance of the air purifier (air exchange rate) also decreases.

Key features

  • Dust protection system for dust extraction and negative pressure maintenance in rooms
  • Easy and quick mounting (quick acting closure)
  • Two integrated dust extraction openings
  • Many different combinations possible (from connection of a ventilator to a filter)
  • High air rate possible
  • Easy transport with carrier bag
  • Easy cleaning

Product specifications

Specifications Units DCS-PV 3000
Air flow
m³/h
3.102
Air pressure
Pa
501
Fan type
Axial
Power consumption
kW
0.62
Power supply
V/Hz
230/1ph/50
Rated current
A
2.89
Protection class
IP44
Sound level
dB(A)
78
Hose
Ømm
305
Recommended number of ducts ( 7.6m)
piece
5
Box size (l x w x h)
mm
800 x 600 x 1250
Net weight
kg
35