Dantherm HPP-i 8-12-16 – inverter swimming pool heat pumps
The low energy consumption coupled with high heat production makes the HPP-i heat pump an environmentally friendly way to heat your swimming pool.
Unlike alternative ways of heating pools, the HPP-i heat pump requires no fuel storage tank or high capacity electrical supply. It produces no smell, fumes or CO2 gases. HPP-i heat pumps are designed to work all year round when temperatures are above -5°C. Thus, the pool season can be extended for several months.
Dantherm HPP-i 12-16-22-28 – inverter swimming pool heat pumps
|
Dantherm HPP-i front view
|
Dantherm HPP-i side view
|
Dantherm HPP control panel
|
Dantherm inverter temperature control graph
|
Dantherm heating method efficiency chart
|
Pool Therm App home screen
|
Key features
-
Inverter heat pump
-
Average COP >8.8 = 2 x more efficient than on/off heat pumps
-
Eco-friendly refrigerant R32 = 675 GWP, (Global Warming Potential)
-
Performance ratings from 9.5 to 20kW
-
9-11 dB(A) sound reduction compared to an equivalent on/off heat pump, with ‘Whisper Mode’
-
Multifunction operation functions can be set to heating, heat/cool and cooling
-
Soft start-up
-
Aluminium alloy
-
Built-in Wi-Fi module
-
PoolTherm App is available on Android and iOS
New refrigerant gas
-
Has a low GWP (675)
-
Zero ozone depleting potential (ODP)
-
Is F-gas phase-down compliant
-
Requires less refrigerant volume per kW
-
Is easier to reuse and recycle
Rapid installation, flexible operation
Dantherm HPP-i heat pumps are easy to install and fully self-contained units. When it comes to operation, the HPP-i units offer a quiet, high efficient, reliable, and safe performance.
Controls
The HPP-i heat pump has an integrated controller with a touchscreen user interface. The basic functions are:
- Function settings for: Heating, cooling or heat/cool
- Parameter adjustment
Product specifications
Specifications | Units | HPP-i 8 |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
12-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
9.5
|
COP range |
|
13.2-5.4
|
Average COP at 50% speed |
|
8.9
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
7
|
COP range |
|
6.9-4.2
|
Average COP at 50% speed |
|
6.3
|
Performance @ air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
4.5
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
3.9
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.3-1.79
|
Rated input current |
A
|
1.38-7.58
|
Maximum input current |
A
|
9.5
|
Water flow |
m³/h
|
3.0-5.0
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight |
g
|
600
|
Sound level @ 10m |
dB(A)
|
19.6-31.5
|
Product size (w x d x h) |
mm
|
864 x 359 x 648
|
Weight |
kg
|
47
|
Specifications | Units | HPP-i 12 |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
12-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
13.0
|
COP range |
|
13.5-5.6
|
Average COP at 50% speed |
|
9.7
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
9.5
|
COP range |
|
7.0-4.0
|
Average COP at 50% speed |
|
6.1
|
Performance @ air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
5.6
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
5.2
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.40-2.38
|
Rated input current |
A
|
1.82-10.80
|
Maximum input current |
A
|
12.5
|
Water flow |
m³/h
|
4.0-6.0
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight |
g
|
900
|
Sound level @ 10m |
dB(A)
|
21.9-32.0
|
Product size (w x d x h) |
mm
|
864 x 359 x 648
|
Weight |
kg
|
49
|
Specifications | Units | HPP-i 16 |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
12-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
20.0
|
COP range |
|
13.5-5.7
|
Average COP at 50% speed |
|
9.3
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
13.5
|
COP range |
|
7.0-4.2
|
Average COP at 50% speed |
|
6.3
|
Performance @ air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
7.9
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
7.4
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.57-3.21
|
Rated input current |
A
|
2.60-14.61
|
Maximum input current |
A
|
19.5
|
Water flow |
m³/h
|
7.0-10.0
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight |
g
|
1100
|
Sound level @ 10m |
dB(A)
|
24.3-36.1
|
Product size (w x d x h) |
mm
|
954 x 359 x 748
|
Weight |
kg
|
68
|