Free air cooling technology

7 min lest
Dantherm telecoms cooling web

Free cooling equals cost-effective controlled ventilation for telecom site because of their ability to cool by means of ambient air without a compressor. Dantherm free cooling solutions operate with an overpressure, delivering filtered air into the room, thereby ensuring a clean environment, for example for radio transmission equipment. Energy savings can be huge – with our Flexibox units we can document energy and operating cost savings of up to 90% at Telecom sites that are hosting networks like GSM, UMTS or LTE.

The impressive reduction in energy consumption stems is most often a result of comparing the free air cooling unit technology to Telecom sites that have previously applied traditional air-conditioners. By using free cooling, the overall thermal management running expenditure is simply slashed by this impressive percentage.

How does free cooling work?

Free cooling solutions create a fine-filtered overpressure. Motorised dampers are recommended to ensure optimum air flow in the shelter and to prevent ambient air from entering the shelter or room.

Total heat management

The free cooling solutions provide the option of total heat management in the telecom shelter, as the system controls both connected heating and air conditioning systems. Even surveillance and alarms are part of the free cooling solution.


6th generation of free cooling technology

The free cooling technology has been used by Dantherm for more than a decade and has been through 6 design generations resulting in vastly improved and optimised solutions that stand on years of accumulated knowhow.

Capacity

When choosing a cooling technology that utilizes ambient air to cool, it is important to understand the concept of delta t (Δt):

Δt = t internal - t ambient

The capacity is stated as e.g. 288 W/K. This means that by a difference in temperature of 1Kelvin = 1°C, the cooling capacity is 0.288kW.

Example: Average ambient temperature: 20°C, desired internal temperature: 25°C = Δt = 5 (25-20).

Humidity

Humidity in relation to free cooling is a frequently asked question. When using free cooling, you may apply humid and cold ambient air into an electronic enclosure to cool it down. When the humid ambient air meets the warm air in the enclosure, it is heated and the relative humidity will decrease – leaving no risk for condensation on the electronic equipment.

Installing a free cooling unit like Dantherm’s Flexibox at an existing site will:

  • Lower maintenance costs for the complete cooling system as the unit will be relieving the existing air-conditioner from some of its hard and expensive work
  • Extend air-conditioner lifetime because of the above
  • Less emergency trips to sites due to air-conditioner breakdowns
  • Limit site breakdowns as it will also act as emergency cooling in case of air-conditioner breakdown or power outage, thereby securing a longer “up-time” in case of overheating
  • Give technicians longer reaction time to arrive at site before site breakdown

For help choosing the right system for your project, don’t hesitate to get in touch with our team.

Relaterte produkter

Dantherm Flexibox 810 med hette – Frikjølingenhet
Dantherm climate soloutions tab flip

Frikjøling

Frikjøling er kostnadseffektiv kontrollert ventilasjon – telekomoppbevaring eller -kabinettet kjøles ned ved hjelp av omgivelsesluft uten kompressor.

Dantherm DFC 350 – fortrengningsfrikjøling
Dantherm climate soloutions tab flip

Fortrengningsfrikjøling

Dantherm DFC 350 og 450 er slanke passive kjøleenheter som bruker den fortrengningsfrie luftkjølingsteknologien.

Dantherm TKS 60 – Fritt kylaggregat med hög prestanda
Dantherm climate soloutions tab flip

Frikjøling med høy kapasitet

TKS 60 er en luftkjøling med høy kapasitet som er konstruert for å kontrollere det interne miljøet i kommunikasjonsrom med et minimum av energi.

Dantherm Air Maze Terning– værbeskyttelse for lufteventil
Dantherm climate soloutions tab flip

Værbeskyttelse for lufteventil

AirMaze er en kompakt luftbanebeskyttelse som kan fjerne vinddrevne vann- og sandpartikler fra utstyr med høy lufthastighet.

Relevante artikler

Om kjøling av telekomutstyr
Dantherm climate soloutions tab

Hvorfor frikjøling bruker mindre energi på å holde elektroniske enheter kjølige enn tradisjonelle kl...

Photo of Tobias Netz
Tobias Netz 8 min lest
Dantherm elektronisk kabinett, nett
Dantherm climate soloutions tab

Monoblokk og delt klimaanlegg for telekom

Photo of Tobias Netz
Tobias Netz 4 min lest
Dantherm building
Dantherm climate soloutions tab

A quick comparison between the two technologies

Photo of Tobias Netz
Tobias Netz 5 min lest

Kontakt en ekspert

Trenger du hjelp til å finne riktig løsning? Vårt team med mer enn 100 klimakontrolleksperter står klare til å hjelpe deg.
Du kan også kontakte oss eller delta i diskusjonen i våre sosiale medier. Se vår LinkedIn-side.