Heylo DCS-PF 1000 – dust control system

Dust control system with filter

Including: DCD-3.0 (Door base element + 2x PVC foil incl. velcro fastener + transport bag) + air cleaner PF 1000 + coarse air filter + fine dust filter (F9/class M) / optional Hepa filter (H14/class H) + hose (length 7.6m)

Dust extraction and low pressure maintenance in rooms - quickly installed. Suitable for door widths up 680 to 1430mm. Optional expansible by door adapters.

Finally renovate cleanly! If you want to remove dust quickly and safely from your working area during restoration work and you want to protect other parts of the building, the dust control system DCS is exactly what you need.

The main part is Dust Protection Door DCD-3.0 - for quick and safe sealing of doors between the working or dirty area and the white area. By connecting the ventilators in the white area, a low pressure is produced in the renovation area (black area) which prevents that fine dust can spread to neighbouring rooms. As soon as the hose is passed through the opening directly to the source of the dust in he renovation area, a dust extraction function occurs.

Easy transport and quick installation, DCS saves time, money and complications. Extensive cleaning afterwards which is required in case of water-based system is not required - simply beat out or dispose of the dust bags.

Heylo dust control system DCS-PF 1000
Heylo dust control system DCS-PF 1000
Heylo dust control door DCD-3.0
Heylo dust control door DCD-3.0
Heylo air cleaner PF 1000
Heylo air cleaner PF 1000

Frequently asked questions (FAQs) about dust protection

What is the difference between the white area and the black area?
"Black area" refers to the contaminated (construction site) area. Hazardous substances arising during remediation include asbestos, dusts or mould. "White area" refers to the rooms located outside the contaminated remediation area.

In order to protect the workman and the occupants of the house, the white area is separated from the black area by partitions so that they are not contaminated. Air purifiers are used to ensure occupational safety within the black area. The black/white principle is laid down in corresponding regulations, for example in TRGS 524 (protective measures for activities in contaminated areas) and TRGS 519 (asbestos: demolition, renovation or maintenance work).

How does negative pressure work? Why do I need negative pressure in the work area?
Negative pressure in the work area prevents dust particles from entering adjacent rooms. With negative pressure, the air only flows into the room (work area) from the outside. Fine dust particles that are in the room air of the work area have no chance of getting out of the area.

When do I need a dust control door (DCD), when the dust control wall (HEYWALL)?
The DCD (Dust Control Door) is a door bulkhead that replaces a room door. When in use, the room is separated by a sheet and is easy to walk through. In combination with an air purifier used to maintain negative pressure, the door bulkhead is an effective dust barrier. The hoses of the air purifier are routed through the DCD to the point of dust generation, resulting in extraction at the workplace.

The HEYWALL is a dust barrier that can be used to reduce the size of large rooms or to separate refurbishment areas from others. With easy-to-install telescopic poles, a sheet can be used as a vertical partition to flexibly separate the room. Different construction variants can be realised with the flexible system: L-shape, U-shape, polygon, room divider or airlock. The system can always be reused, supplemented and extended. Special clamps can be used for the contact surfaces on the sides and on the ceiling. Here, too, the dust-tightness increases considerably with the use of an air purifier. If the rooms have been reduced in size with the system, the requirement for the performance of the air purifier (air exchange rate) also decreases.

Key features

  • For dust extraction and negative pressure maintenance in rooms
  • For mould remediation, HEPA filter H14 can also be used as an option
  • Suitable for door widths from 680-1430mm
  • Extendable by door adapter
  • Two openings for dust extraction
  • High air flow possible
  • Easy and quick installation of the dust protection door due to quick release fastener
  • Easy cleaning

Product specifications

Specifications Units DCS-PF 1000
Ventilator-air flow without filters
m³/h
917
Air flow with free M-filter F9
m³/h
760
Air flow with free H-filter H14
m³/h
515
Air flow by saturated filters
m³/h
346
Power consumption
kW
0.185
Power supply
V/Hz
230/1ph/50
Rated current
A
1.33
Protection class
IP44
Sound level
dB(A)
0-66
Hose intake/outlet side
Ømm
205
Box size (l x w x h)
mm
800 x 600 x 1250
Net weight
kg
35