The AC-M11 air-conditioner is a portable unit developed primarily to provide air-conditioning in temporary or transportable buildings or tents.

The AC-M11 is a small, light-weight aluminium unit built into a rigid steel frame. The unit is designed for outside installation with ducted supply and return air.

View our range of air cooling units and tent coolers suitable for all types of application and commercial purpose on any scale.

Dantherm AC-M11 – tent cooler
Dantherm AC-M11 – tent cooler
Dantherm AC-M11 white version
Dantherm AC-M11 white version
Dantherm climate solutions for field camps
Dantherm climate solutions for field camps
Dantherm AC-M11 with ducting
Dantherm AC-M11 with ducting
Dantherm AC-M11 tent installation
Dantherm AC-M11 tent installation
AC-M air conditioner animation
AC-M air conditioner animation

Key features

  • Designed for optimal utilization of a standard 20" ISO container
  • The AC-M11 is built into a strong metal frame with insulated panels where relevant, powder coated
  • Top finish painting is standard sand colour
  • Option with built in heating will heat when ambient temperature is below 20°C
  • Scroll compressor for a high degree of reliability and low noise level
  • Automatic phase surveillance
  • Sequential start of units possible
  • HP/LP pressostat switches ensuring long compressor lifetime
  • Fresh air intake
  • Four way fork lift handling

Product specifications (metric)

SpecificationsUnitsAC-M11  (400V/3ph/50Hz)
Registered NSN number
Yes
Operating temperature range, cooling
°C
20 to 60
Operating temperature range, heating
°C
-32 to 20
Air flow
m³/h
1700
Fresh air intake (two adjustable dampers)
m³/h
0 to 200
Sound level @ 1m
dB(A)
55
Sound level @ 1.5m
dB(A)
-
Protection class
IP
IPX5
Refrigerant
kg
R134a/2.0
Max refrigerant pressure
bar
-
Global Warning Potential
AR4
1430
Nominal cooling capacity
kW
11
Heating capacity
kW
8 (optional)
Power supply
V/Hz
400/3ph/50
Max. running current, cooling/heating
A
14 / 13.8
Locked rotor amperage (LRA)
A
48
Start inrush current with soft starter
A
-
Max inrush current with soft starter
A
37
Max. power consumption cooling/heating
W
5600 / 8700
Main plug, IEC/EN 60 309
A
-
Power cable length
m
10
Operation height (above sea level)
m
-
Long term storage
°C
-
Hose connection
Ømm
315
Product size (h x l x w)
mm
735 x 1,140 x 1,140
Weight
kg
162
SpecificationsUnitsAC-M11  (208V/3ph./60Hz) 
Registered NSN number
Yes
Operating temperature range, cooling
°C
20
Operating temperature range, heating
°C
-32 to 55
Air flow
m³/h
1700
Fresh air intake (two adjustable dampers)
m³/h
0 to 200
Sound level @ 1m
dB(A)
-
Sound level @ 1.5m
dB(A)
59
Protection class
IP
X5
Refrigerant
kg
R513A / 2.0
Max refrigerant pressure
bar
28
Global Warning Potential
AR4
631
Nominal cooling capacity
kW
11
Heating capacity
kW
8
Power supply
V/Hz
208/3ph/60
Max. running current, cooling/heating
A
20.5 / 22.7
Locked rotor amperage (LRA)
A
65.5
Start inrush current with soft starter
A
29
Max inrush current with soft starter
A
-
Max. power consumption cooling/heating
W
-
Main plug, IEC/EN 60 309
A
30
Power cable length
m
-
Operation height (above sea level)
m
0 to 3500
Long term storage
°C
-40 to +70°C <50%RH
Hose connection
Ømm
315
Product size (h x l x w)
mm
780 x 1140 x 1140
Weight
kg
173

Product specifications (imperial)

SpecificationsUnitsAC-M11  (400V/3ph/50 Hz)
Registered NSN number
-
Yes
Operating temperature range, cooling
ºF
68 to 140
Operating temperature range, heating
ºF
-26 to 68
Air flow
CFM
1000
Fresh air intake (two adjustable dampers)
CFM
0 to 120
Sound level @ 1m
dB(A)
55
Sound level @ 1.5m
dB(A)
-
Protection class
NEMA
3R
Refrigerant
lbs
R134a/4.4
Max refrigerant pressure
psi
-
Global Warning Potential
AR4
1430
Nominal cooling capacity
BTU
37500
Heating capacity
BTU
27000
Power supply
V/Hz
400/3ph/50
Max. running current, cooling/heating
A
14 / 13.8
Locked rotor amperage (LRA)
A
48
Start inrush current with soft starter
A
-
Max inrush current with soft starter
A
37
Max. power consumption cooling/heating
W
5,600 / 8,700
Main plug, IEC/EN 60 309
A
-
Power cable length
ft
32.8
Operation height (above sea level)
ft
-
Long term storage
ºF
-
Hose connection
Øin
12.4
Product size (h x l x w)
In
28.3 x 44.9 x 44.9
Weight
lbs
357
SpecificationsUnitsAC-M11  (208V/3ph./60 Hz) 
Registered NSN number
-
Yes
Operating temperature range, cooling
ºF
68 to 136
Operating temperature range, heating
ºF
-26 to 68
Air flow
CFM
1000
Fresh air intake (two adjustable dampers)
CFM
0 to 120
Sound level @ 1m
dB(A)
-
Sound level @ 1.5m
dB(A)
59
Protection class
NEMA
3R
Refrigerant
lbs
R513A / 7.7
Max refrigerant pressure
psi
406
Global Warning Potential
AR4
631
Nominal cooling capacity
BTU
37500
Heating capacity
BTU
27300
Power supply
V/Hz
208/3ph/60
Max. running current, cooling/heating
A
20.5 / 22.7
Locked rotor amperage (LRA)
A
65.5
Start inrush current with soft starter
A
29
Max inrush current with soft starter
A
-
Max. power consumption cooling/heating
W
-
Main plug, IEC/EN 60 309
A
30
Power cable length
ft
-
Operation height (above sea level)
ft
0 to 11480
Long term storage
ºF
-40 to +158 <50%RH
Hose connection
Øin
12.4
Product size (h x l x w)
In
28.3 x 44.9 x 44.9
Weight
lbs
381

Suitable for

  • Camps and field hospitals
  • Events and festivals