Free cooling equals cost-effective controlled ventilation for telecom site because of their ability to cool by means of ambient air without a compressor. Dantherm free cooling solutions operate with an overpressure, delivering filtered air into the room, thereby ensuring a clean environment, for example for radio transmission equipment. Energy savings can be huge – with our Flexibox units we can document energy and operating cost savings of up to 90% at Telecom sites that are hosting networks like GSM, UMTS or LTE.

The impressive reduction in energy consumption stems is most often a result of comparing the free air cooling unit technology to Telecom sites that have previously applied traditional air-conditioners. By using free cooling, the overall thermal management running expenditure is simply slashed by this impressive percentage.

How does free cooling work?

Free cooling solutions create a fine-filtered overpressure. Motorised dampers are recommended to ensure optimum air flow in the shelter and to prevent ambient air from entering the shelter or room.

Total heat management

The free cooling solutions provide the option of total heat management in the telecom shelter, as the system controls both connected heating and air conditioning systems. Even surveillance and alarms are part of the free cooling solution.


6th generation of free cooling technology

The free cooling technology has been used by Dantherm for more than a decade and has been through 6 design generations resulting in vastly improved and optimised solutions that stand on years of accumulated knowhow.

Capacity

When choosing a cooling technology that utilizes ambient air to cool, it is important to understand the concept of delta t (Δt):

Δt = t internal - t ambient

The capacity is stated as e.g. 288 W/K. This means that by a difference in temperature of 1Kelvin = 1°C, the cooling capacity is 0.288kW.

Example: Average ambient temperature: 20°C, desired internal temperature: 25°C = Δt = 5 (25-20).

Humidity

Humidity in relation to free cooling is a frequently asked question. When using free cooling, you may apply humid and cold ambient air into an electronic enclosure to cool it down. When the humid ambient air meets the warm air in the enclosure, it is heated and the relative humidity will decrease – leaving no risk for condensation on the electronic equipment.

Installing a free cooling unit like Dantherm’s Flexibox at an existing site will:

  • Lower maintenance costs for the complete cooling system as the unit will be relieving the existing air-conditioner from some of its hard and expensive work
  • Extend air-conditioner lifetime because of the above
  • Less emergency trips to sites due to air-conditioner breakdowns
  • Limit site breakdowns as it will also act as emergency cooling in case of air-conditioner breakdown or power outage, thereby securing a longer “up-time” in case of overheating
  • Give technicians longer reaction time to arrive at site before site breakdown

For help choosing the right system for your project, don’t hesitate to get in touch with our team.

Produits associés

Dantherm Flexibox 810 avec hotte – unité de ventilation à refroidissement libre
Dantherm climate soloutions tab flip

Refroidissement

Le refroidissement libre représente une ventilation contrôlee rentable : l'abri ou l'espace fermé pour équipements de télécommunications est refroidi par l'air ambiant, sans utilisation d'un compresseur.

Dantherm DFC 350 – refroidissement sans déplacement
Dantherm climate soloutions tab flip

Refroidissement sans déplacement

Les unités Dantherm DFC 350 et 450 sont des unités de refroidissement passives minces utilisant la technologie de refroidissement à air libre par déplacement.

Dantherm TKS 60 – unité de refroidissement à air libre de haute capacité
Dantherm climate soloutions tab flip

Refroidissement haute capacité

Le TKS 60 est un système de refroidissement à air libre haute capacité conçu pour contrôler l’environnement interne des abris de communication en utilisant un minimum d’énergie.

Cube Dantherm Air Maze – protection contre les intempéries de la bouche d'aération
Dantherm climate soloutions tab flip

Protection contre les intempéries de la bouche d'aération

L'AirMaze est une protection compacte du débit d'air capable d’éliminer l’eau et les particules de sable entraînées par le vent, même dans les applications impliquant de l'air à grande vitesse.

Aperçus recommandés

Insights Content telecom cooling
Dantherm climate soloutions tab

Why free cooling keeps electronic devices cool for less than traditional air conditioning systems

Photo of Tobias Netz
Tobias Netz lecture de 8 min
Dantherm electronic cabinet web
Dantherm climate soloutions tab

Monoblock and split air-conditioning solutions for telecoms

Photo of Tobias Netz
Tobias Netz lecture de 4 min
Dantherm building
Dantherm climate soloutions tab

A quick comparison between the two technologies

Photo of Tobias Netz
Tobias Netz lecture de 5 min

Faites appel à un expert

Besoin d'aide pour choisir la bonne solution ? Notre équipe de plus de 100 experts en solution pour le climat peut vous aider.
Vous pouvez également contacter ou rejoindre la discussion sur nos réseaux sociaux. Consultez notre page LinkedIn.