Dantherm Group
Dantherm

Dantherm HCV 700 – residential ventilation unit

Wall mounted home ventilation units

The HCV 700 is a highly efficient residential ventilation unit for houses, villas, and apartments of up to 450m2 or more. It comes supplied as a packaged basic ventilation unit complete with built-in control panel, and are delivered with all parts necessary for wall installation. The HCV 700 is ideal for free wall installation with minimum 700mm space. A standard wall rail is supplied with all units.

Dantherm HCV 700 – residential ventilation unit
Dantherm HCV 700 – residential ventilation unit
Dantherm HCV calibration via pc tool
Dantherm HCV calibration via pc tool
Dantherm HCV calibration using control panel
Dantherm HCV calibration using control panel
HCV 400 why choose an enthalpy heat exchanger
HCV 400 why choose an enthalpy heat exchanger
HCV 400 how to install a preheater
How to use the control panel on the Dantherm HCV series
How to change filter in Dantherm Home Ventilation units
How to change filter in Dantherm Home Ventilation units
Dantherm HCV filter timer reset
Dantherm HCV filter timer reset
Dantherm Residential App
Dantherm Residential App

Key features

  • Demand-controlled ventilation with integrated humidity sensor, reducing power consumption at times with low ventilation demands
  • Summer mode, in which supply fan is stopped and any open window will supply cooler outside air, lowering the room temperature
  • Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality
  • High-efficiency heat recovery
  • EC fan motors with extremely low energy consumption (low SPI)
  • Easy-to-install and commission solution with built-in air pressure spigots for easy calibration
  • Highly customizable units, with the option to add a high variety of internal as well as external accessories
  • A standard wall rail is supplied with the unit

Product specifications

Specifications Units HCV 700
Max. achievable flow at 100Pa
V100Pa | m³/h
550
Max. declared flow at 100Pa
Vmax.rated | m³/h
450
Recommended operating range
V | m³/h
80 - 450
EN 13141-7 reference flow at 50Pa
VREF | m³/h
315
Performance
Thermal efficiency in accordance with EN13141-7
ηSUP | %
85
Specific power consumption in accordance with EN13141-7
SFP | m³/h
0.22
Leakage (external and internal) in accordance with EN13141-7
%
<2% (Class A1)
Filters in accordance with ISO16890
-
ISO Coarse 75% (optional optional on supply: ePM1>50% )
Filters in accordance with EN779
-
G4 (optional on supply: F7)
Installation ambient temperature
tSURR | °C
+12 to +50
Outdoor temperature without preheater installed
tODA | °C
-12 to +50
(The use of the preheating coil is recommended at outdoor temperatures below -3°C to ensure balanced operation.)
Outdoor temperature with preheater installed
tODA | °C
-20 to +50
Maximum absolute humidity in extract air
x | g/kg
10
Cabinet
Dimensions (without wall bracket)
w x d x h | mm
700 x 750 x 1050
Spigots/duct connections
Ømm
200 – female
Weight
kg
70
Thermal conductivity – polystyrene insulation
λ | W/mK
0.031
Heat transition figures – polystyrene insulation
U | W/m²K
<1
Fire classification of the polystyrene insulation
class
DIN 4102-1 class B2 EN 13501 class E
Drainage hose
Ø/length | "/mm
¾ / 1
Cabinet colour
RAL
9016
Electrical
Voltage
U | V
230
Maximum power consumption without/with preheater
P | W
234/1834
Frequency
f | Hz
50
Protection class
-
IP21