Dantherm HCV 460 P2 – residential ventilation unit
Wall-mounted home ventilation units
The HCV 460 P2 is a highly efficient residential ventilation unit for houses, villas, and apartments of up to 450m2 or more. It comes supplied as a packaged basic ventilation unit complete with built-in control panel, and is delivered with all parts necessary for wall installation. The HCV 460 P2 also fits perfectly in a 60 x 60cm cupboard.
Dantherm HCV 460
|
Dantherm HCV calibration via pc tool
|
Dantherm HCV calibration using control panel
|
HCV 400 why choose an enthalpy heat exchanger
|
How to use the control panel on the Dantherm HCV series
|
How to change filter in Dantherm Home Ventilation units
|
Dantherm HCV filter timer reset
|
Dantherm Residential App
|
Key features
-
Demand-controlled ventilation with integrated humidity sensor, reducing power consumption at times with low ventilation demands
-
Summer mode in which supply fan is stopped and any open window will supply cooler outside air, lowering the room temperature
-
Fireplace mode, creating a temporary inside overpressure to enhance chimney functionality
-
High-efficiency heat recovery
-
EC fan motors with extremely low energy consumption (low SPI)
-
Easy-to-install and commission solution with built-in air pressure spigots for easy calibration
-
Highly customizable units with the option to add a high variety of internal as well as external accessories
-
The HCV 460 takes up only as little space as a 60 x 60cm cupboard
Product specifications
Specifications | Units | HCV 460P2 |
---|---|---|
Max. achievable flow at 100Pa |
V100Pa | m³/h
|
460
|
Max. declared flow at 100Pa |
Vmax. rated | m³/h
|
360
|
Operating range DIBt |
VDIBt | m³/h
|
70 - 360
|
Operating range Passivhaus at 100Pa |
VPHI | m³/h
|
106 - 270
|
EN 13141-7 reference flow at 50Pa |
VREF | m³/h
|
252
|
Performance | ||
Thermal efficiency in accordance with EN13141-7 |
ηSUP | %
|
86
|
Leakage (external and internal) in accordance with EN13141-7 |
| %
|
<2% (Class A1)
|
Filters in accordance with ISO16890 |
-
|
ISO Coarse 75% (optional optional on supply: ePM1>50% )
|
Filters in accordance with EN779 |
-
|
G4 (optional on supply: F7)
|
Installation surrounding temperature |
tSURR | °C
|
+12 to +50
|
Outdoor temperature without preheater installed |
tODA | °C
|
-12 to +50
(The use of the preheating coil is recommended at outdoor temperatures below -3°C to ensure balanced ventilation)
|
Outdoor temperature with preheater installed |
tODA | °C
|
-20 to +50
|
Maximum absolute humidity in extract air |
x | g/kg
|
10
|
Cabinet | ||
Dimensions (without bracket) |
mm
|
540 x 549 x 1050
(+20mm fitting)
|
Spigots/duct connections |
Ømm
|
160 – female
|
Weight |
kg
|
40
|
Thermal conductivity – polystyrene insulation |
λ | W/mK
|
0.031
|
Heat transition figures – polystyrene insulation |
U | W/m2K
|
U<1
|
Fire classification of the polystyrene insulation |
-
|
DIN 4102-1 class B2
EN 13501 class E
|
Drainage hose (included) |
Ø/length | "/m
|
¾/1
|
Cabinet colour |
RAL
|
9016 / galvanized metal grey
|
Electrical | ||
Voltage |
U | V
|
230
|
Maximum power consumption (without/with preheater) |
P | W
|
230/2080
|
Frequency |
f | Hz
|
50
|
Protection class |
-
|
IP21
|