Dantherm HCC 360P2 – residential ventilation unit
Ceiling and wall-mounted home ventilation units
The HCC 360P2 is a unique and flexible residential ventilation solution. With only 30cm installation headroom it is ideal for installation in suspended ceilings or onto a wall, even hidden inside a closet. The unit can be electronically reversed, meaning that both air flows will be reversed. This allows the same unit type to be mounted with the inside/outside ducts connected to either the right or the left hand side of the unit. Electrical connections can be connected from either the left or the right.
Dantherm HCC 360
|
Dantherm HCC 360
|
Dantherm HCC access panel – residential ventilation unit
|
Key features
-
High efficiency heat recovery – up to 85%
-
EC fan motors with low energy consumption (low SPI)
-
Only 300mm installation headroom height is required
-
Time controlled ventilation level, based on 11 different built-in pre-programmed week programs, reducing power consumption in periods with low ventilation demands
-
Summer cooling mode
-
Fireplace mode, creating a momentary inside overpressure, to enhance chimney functionality
-
Easy-to-install and commissioning solution with built in air measure ports, for easy balancing with PC-Tool
-
Electronically left/right fan direction switching, allowing same unit type to adapt any physical installation requirements, regardless of ceiling and wall selection
-
TCP/IP ModBus connection, for inter-operation with Building Management System
-
Electrical connections can be connected from either the left or the right.
Product specifications
Specifications | Units | HCC 360P2 |
---|---|---|
Max. achievable flow at 100Pa |
V100Pa| m³/h
|
360
|
Max. declared flow at 100Pa |
Vmax.rated| m³/h
|
220
|
Recommended operating range |
V | m³/h
|
50 - 220
|
EN 13141-7 referensflöde vid 50Pa |
VREF | m³/h
|
154
|
Performance | ||
Thermal efficiency EN 13141-7 at reference flow |
ηEN | %
|
88
|
Leakage (external and internal) according to EN 13141-7 |
class
|
<2% (Class A1)
|
Filters in accordance with ISO16890 |
-
|
ISO Coarse 75% (optional on supply: ePM1>50%)
|
Filters in accordance with EN779 |
-
|
G4 (optional on supply: F7)
|
Installation surrounding temperature range |
tSURR | °C
|
+12 to +40
|
Maximum humidity in extract air at 25°C |
RH %
|
55
|
Outdoor temperature range without preheating installed |
tODA | °C
|
-12 to +45
(The use of the preheating coil is recommended at outdoor temperatures below -3°C to ensure balanced ventilation)
|
Outdoor temperature range with preheating installed |
tODA | °C
|
-15 to +45
|
Cabinet | ||
Dimensions (without wall bracket) |
w x d x h | mm
|
600 x 279 x 1122
|
Spigots/duct connections |
Ømm
|
125 – female
|
Weight |
kg
|
34
|
Heat conductivity – polystyrene insulation |
λ | W/mK
|
0.031
|
Heat transfer coefficient – polystyrene insulation |
U | W/m2K
|
<1
|
Drainage hose (accessory) |
Ø | "
|
½
|
Cabinet colour |
RAL
|
galvanized metal grey
|
Fire classification of the polystyrene insulation |
|
DIN 4102-1 class B2
EN 13501 class E
|
Electrical | ||
Voltage |
U | V
|
230
|
Maximum power consumption (without/with preheater) |
P | W
|
161/1061
|
Frequency |
f | Hz
|
50
|
Protection class |
-
|
IP20
|