Dantherm Group
Dantherm

Dantherm HCC 360P2 – residential ventilation unit

Ceiling and wall-mounted home ventilation units

The HCC 360P2 is a unique and flexible residential ventilation solution. With only 30cm installation headroom it is ideal for installation in suspended ceilings or onto a wall, even hidden inside a closet. The unit can be electronically reversed, meaning that both air flows will be reversed. This allows the same unit type to be mounted with the inside/outside ducts connected to either the right or the left hand side of the unit. Electrical connections can be connected from either the left or the right.

Dantherm HCC 260P1 360P1 360P2 – residential ventilation unit
Dantherm HCC 360
Dantherm HCC 2 with PC Tool HPT 1 – residential ventilation unit
Dantherm HCC 360
Dantherm HCC access panel – residential ventilation unit
Dantherm HCC access panel – residential ventilation unit

Key features

  • High efficiency heat recovery – up to 85%
  • EC fan motors with low energy consumption (low SPI)
  • Only 300mm installation headroom height is required
  • Time controlled ventilation level, based on 11 different built-in pre-programmed week programs, reducing power consumption in periods with low ventilation demands
  • Summer cooling mode
  • Fireplace mode, creating a momentary inside overpressure, to enhance chimney functionality
  • Easy-to-install and commissioning solution with built in air measure ports, for easy balancing with PC-Tool
  • Electronically left/right fan direction switching, allowing same unit type to adapt any physical installation requirements, regardless of ceiling and wall selection
  • TCP/IP ModBus connection, for inter-operation with Building Management System
  • Electrical connections can be connected from either the left or the right.

Product specifications

Specifications Units HCC 360P2
Max. achievable flow at 100Pa
V100Pa| m³/h
360
Max. declared flow at 100Pa
Vmax.rated| m³/h
220
Recommended operating range
V | m³/h
50 - 220
EN 13141-7 referensflöde vid 50Pa
VREF | m³/h
154
Performance
Thermal efficiency EN 13141-7 at reference flow
ηEN | %
88
Leakage (external and internal) according to EN 13141-7
class
<2% (Class A1)
Filters in accordance with ISO16890
-
ISO Coarse 75% (optional on supply: ePM1>50%)
Filters in accordance with EN779
-
G4 (optional on supply: F7)
Installation surrounding temperature range
tSURR | °C
+12 to +40
Maximum humidity in extract air at 25°C
RH %
55
Outdoor temperature range without preheating installed
tODA | °C
-12 to +45
(The use of the preheating coil is recommended at outdoor temperatures below -3°C to ensure balanced ventilation)
Outdoor temperature range with preheating installed
tODA | °C
-15 to +45
Cabinet
Dimensions (without wall bracket)
w x d x h | mm
600 x 279 x 1122
Spigots/duct connections
Ømm
125 – female
Weight
kg
34
Heat conductivity – polystyrene insulation
λ | W/mK
0.031
Heat transfer coefficient – polystyrene insulation
U | W/m2K
<1
Drainage hose (accessory)
Ø | "
½
Cabinet colour
RAL
galvanized metal grey
Fire classification of the polystyrene insulation
DIN 4102-1 class B2 EN 13501 class E
Electrical
Voltage
U | V
230
Maximum power consumption (without/with preheater)
P | W
161/1061
Frequency
f | Hz
50
Protection class
-
IP20