Dantherm AC-M18 – tent cooler
Tent cooler
The AC-M18 air-conditioner is a portable unit developed primarily to provide air-conditioning in temporary or transportable buildings or tents. It is a compact, light-weight aluminium unit built into a rigid steel frame.
The AC-M18 is designed for outside installation with ducted supply and return air. For field hospitals, where the need for filtration is higher than that of normal accommodation, a dual filtration system for the internal air path is available. The ACM 18 is also available as a split system for sealed applications (ACM 18 CBRN).
Dantherm AC-M18 – tent cooler
|
Dantherm AC-M18 green coloured
|
Dantherm AC-M18 white coloured
|
Dantherm climate solutions for field camps
|
AC-M air conditioner animation
|
Dantherm AC-M18 control panel
|
Dantherm AC-M18 air outlet
|
Dantherm AC-M18 installation
|
Key features
-
Designed for optimal utilization of a standard 20" ISO container (24 pcs)
-
The AC-M18 is built into a strong metal frame with insulated panels where relevant, powder coated
-
Top finish painting is standard sand colour
-
Option with built in heating will heat when ambient temperature is below 20°C
-
Scroll compressor for a high degree of reliability and low noise level
-
Automatic phase surveillance
-
Sequential start of units possible
-
HP/LP pressostat switches ensuring long compressor lifetime
-
Fresh air intake
-
Four way fork lift handling
-
Easy strap down on air cargo pallets and stackable (two units on top of each other)
Product specifications
Specifications | Units | AC-M18 (3x400V/50 Hz) |
---|---|---|
Registered NSN number |
-
|
Yes
|
Operating temperature range, cooling |
°C
|
+20 – +60
|
Operating temperature range, heating |
°C
|
-32 – +20
|
Air flow |
m³/h
|
2,500
|
Sound level @ 3m |
dB(A)
|
59
|
Protection class |
|
IPX5
|
Refrigerant |
|
R134a
|
Nominal cooling capacity |
kW/Btu
|
17.5/60,000
|
Heating capacity (optional) |
kW
|
6/16
|
Power supply |
V/Hz
|
400/3ph/50
|
Max. running current, cooling/heating |
A
|
16/26
|
Locked rotor amperage (LRA) |
A
|
73
|
Max. power consumption cooling/heating |
W
|
8,300/variable
|
Hose connection |
Ømm
|
400
|
Product size (h x l x w) |
mm
|
780 x 1450 x 1140
|
Weight |
kg
|
206
|
Specifications | Units | AC-M18 (3x208V/60 Hz) |
---|---|---|
Registered NSN number |
-
|
Yes
|
Operating temperature range, cooling |
°C
|
+20 – +60
|
Operating temperature range, heating |
°C
|
-32 – +55
|
Air flow |
m³/h
|
2,500
|
Sound level @ 3m |
dB(A)
|
59
|
Protection class |
|
IPX5
|
Refrigerant |
|
R407C/R134a
|
Nominal cooling capacity |
kW/Btu
|
17.5/60,000
|
Heating capacity (optional) |
kW
|
6/16
|
Power supply |
V/Hz
|
208/3ph/60
|
Max. running current, cooling/heating |
A
|
33/52
|
Locked rotor amperage (LRA) |
A
|
164
|
Max. power consumption cooling/heating |
W
|
8,300/variable
|
Hose connection |
Ømm
|
400
|
Product size (h x l x w) |
mm
|
780 x 1450 x 1140
|
Weight |
kg
|
206
|
Specifications | Units | AC-M18 (3x400V/60 Hz) |
---|---|---|
Registered NSN number |
-
|
Yes
|
Operating temperature range, cooling |
°C
|
+20 – +60
|
Operating temperature range, heating |
°C
|
-32 – +20
|
Air flow |
m³/h
|
2,500
|
Sound level @ 3m |
dB(A)
|
59
|
Protection class |
|
IPX5
|
Refrigerant |
|
R134a
|
Nominal cooling capacity |
kW/Btu
|
17.5/60,000
|
Heating capacity (optional) |
kW
|
6/16
|
Power supply |
V/Hz
|
400/3ph/60
|
Max. running current, cooling/heating |
A
|
13/26
|
Locked rotor amperage (LRA) |
A
|
72
|
Max. power consumption cooling/heating |
W
|
8,300/variable
|
Hose connection |
Ømm
|
400
|
Product size (h x l x w) |
mm
|
780 x 1450 x 1140
|
Weight |
kg
|
206
|
Product specifications (US)
Specifications | Units | AC-M18 (US) (3x208V/60 Hz) |
---|---|---|
Registered NSN number |
|
Yes
|
Operating temperature range, cooling |
°F
|
68 to 140
|
Operating temperature range, heating |
°F
|
-26 to 68
|
Air flow |
SCFM
|
1.471
|
Sound level @ 3m |
dB(A)
|
59
|
Protection class |
NEMA
|
3S
|
Refrigerant |
|
R407
|
Nominal cooling capacity |
BTU
|
60,000
|
Heating capacity (optional) |
BTU
|
20,500/54,600
|
Power supply |
V/Hz
|
208/3ph/60
|
Max. running current, cooling/heating |
A
|
33/52
|
Locked rotor amperage (LRA) |
A
|
164
|
Max. power consumption cooling/heating |
W
|
8,300/variable
|
Hose connection |
Øin
|
15.75
|
Product size (h x l x w) |
in
|
30.7 x 57.1 x 44.9
|
Weight |
lbs
|
454.2
|
Specifications | Units | AC-M18 (US) (3x400V/60 Hz) |
---|---|---|
Registered NSN number |
|
Yes
|
Operating temperature range, cooling |
°F
|
68 to 140
|
Operating temperature range, heating |
°F
|
-26 to 68
|
Air flow |
SCFM
|
1.471
|
Sound level @ 3m |
dB(A)
|
59
|
Protection class |
NEMA
|
3S
|
Refrigerant |
|
R134a
|
Nominal cooling capacity |
BTU
|
60,000
|
Heating capacity (optional) |
BTU
|
20,500/54,600
|
Power supply |
V/Hz
|
400/3ph/60
|
Max. running current, cooling/heating |
A
|
13/26
|
Locked rotor amperage (LRA) |
A
|
72
|
Max. power consumption cooling/heating |
W
|
8,300/variable
|
Hose connection |
Øin
|
15.75
|
Product size (h x l x w) |
in
|
30.7 x 57.1 x 44.9
|
Weight |
lbs
|
454.2
|