Calorex V-PAC 12-16-22 – inverter swimming pool heat pumps
Top outlet swimming pool heat pumps
Inverter technology allows for efficient control of the pool temperature, and the V-PAC only uses what energy is needed when it is required. High efficiency with modulating step-less inverter compressor giving an average COP of >8.7.
Calorex V-PAC 12-16-22 – inverter swimming pool heat pumps
|
Calorex I PAC V PAC installation animation
|
Calorex V PAC 12 – inverter swimming pool heat pumps
|
Calorex V PAC 12 – inverter swimming pool heat pumps
|
Calorex V PAC 12 – inverter swimming pool heat pumps
|
Calorex V PAC 12 – inverter swimming pool heat pumps
|
Calorex inverter temperature control graph
|
Calorex heating method efficiency chart
|
Key features
-
Average COP >8.7 = 2 x more efficient than on/off heat pumps
-
Eco-friendly refrigerant R32 = 675 GWP, (Global Warming Potential)
-
Inverter heat pump
-
Power ratings from 14 to 24kW
-
9-11 dB(A) sound reduction compared to an equivalent on/off heat pump, with ‘Whisper Mode’
-
Ideal for confined spaces
-
Operates in air temperatures of -5°C to +43°C
-
Integrated controller with a touchscreen user interface
-
Function settings for heating, cooling or heat/cool
-
Soft start-up
-
ABS alloy
New refrigerant gas
-
Has a low GWP (675)
-
Zero ozone depleting potential (ODP)
-
Is F-gas phase-down compliant
-
Requires less refrigerant volume per kW
-
Is easier to reuse and recycle
Product specifications
Specifications | Units | V-PAC 12ALX |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
8-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
14.11
|
COP range |
|
18.5-6.28
|
Average COP at 50% speed |
|
10.7
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
10.64
|
COP range |
|
8.5-5.11
|
Average COP at 50% speed |
|
6.5
|
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
6.6
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
6.0
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.20-2.24
|
Maximum input current |
A
|
12.5
|
Water flow |
m³/h
|
4.97
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight/CO2 equivalent |
kg/t
|
0.8/0.54
|
Sound level @ 10m |
dB(A)
|
<29
|
Product size (w x d x h) |
mm
|
650 x 650 x 835
|
Weight |
kg
|
70
|
Included in the box |
|
Rubber feet, drainage pipe, water union
|
Specifications | Units | V-PAC 16ALX |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
8-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
18.5
|
COP range |
|
18.5-6.03
|
Average COP at 50% speed |
|
10.8
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
13.61
|
COP range |
|
8.4-5.02
|
Average COP at 50% speed |
|
6.4
|
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
9.5
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
7.5
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.23-3.06
|
Maximum input current |
A
|
15.5
|
Water flow |
m³/h
|
6.5
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight/CO2 equivalent |
kg/t
|
0.8/0.54
|
Sound level @ 10m |
dB(A)
|
<30
|
Product size (w x d x h) |
mm
|
650 x 650 x 835
|
Weight |
kg
|
80
|
Included in the box |
|
Rubber feet, drainage pipe, water union
|
Specifications | Units | V-PAC 22ALX |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
8-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
24.4
|
COP range |
|
13.5-5.14
|
Average COP at 50% speed |
|
8.8
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
17.8
|
COP range |
|
6.2-4.14
|
Average COP at 50% speed |
|
4.7
|
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
13.9
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
10.9
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.75-4.75
|
Maximum input current |
A
|
24.5
|
Water flow |
m³/h
|
8.98
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight/CO2 equivalent |
kg/t
|
1.7/1.15
|
Sound level @ 10m |
dB(A)
|
<30
|
Product size (w x d x h) |
mm
|
745 x 752 x 967
|
Weight |
kg
|
95
|
Included in the box |
|
Rubber feet, drainage pipe, water union
|