Calorex I-PAC 8-12-16-22 – inverter swimming pool heat pumps
Small inverter heat pumps
Inverter technology allows for efficient control of the pool temperature, and the I-PAC only uses what energy is needed when it is required. High efficiency with modulating step-less inverter compressor giving an average COP of 9.7.
I-PAC 12
|
Introduction to the I-PAC inverter heat pumps
|
Calorex I PAC V PAC installation animation
|
Calorex I PAC 16 ALX – inverter swimming pool heat pump
|
Calorex I-PAC+ 12-16-22-28 – inverter swimming pool heat pump
|
Calorex I PAC 12 – inverter swimming pool heat pump
|
Calorex I PAC 16 ALX – inverter swimming pool heat pump side view
|
Calorex I PAC – inverter swimming pool heat pump range
|
Calorex I PAC controller
|
Pool Therm App home screen
|
Calorex inverter temperature control graph
|
Calorex heating method efficiency chart
|
Key features
-
Average COP 9.7 = 2 x more efficient than on/off heat pumps
-
Eco-friendly refrigerant R32 = 675 GWP, (Global Warming Potential)
-
Inverter heat pump
-
Power ratings from 9.5 to 25kW
-
9-11 dB(A) sound reduction compared to an equivalent on/off heat pump, with ‘Whisper Mode’
-
Operates in air temperatures of -5°C to +43°C
-
Integrated controller with a touchscreen user interface
-
Function settings for heating, cooling or heat/cool
-
Soft start-up
-
Aluminium alloy
-
Built-in Wi-Fi module
-
PoolTherm App is available on Android and iOS
New refrigerant gas
-
Has a low GWP (675)
-
Zero ozone depleting potential (ODP)
-
Is F-gas phase-down compliant
-
Requires less refrigerant volume per kW
-
Is easier to reuse and recycle
Product specifications
Specifications | Units | I-PAC 8ALX |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
12-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
9.5
|
COP range |
|
13.2-5.4
|
Average COP at 50% speed |
|
8.9
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
7.0
|
COP range |
|
6.9-4.2
|
Average COP at 50% speed |
|
6.3
|
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
4.5
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
3.9
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.3-1.79
|
Maximum input current |
A
|
9.5
|
Water flow |
m³/h
|
3.0-5.0
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight/CO2 equivalent |
kg/tons
|
0.6/0.41
|
Sound level @ 10m |
dB(A)
|
19.6-31.5
|
Product size (w x d x h) |
mm
|
864 x 359 x 648
|
Weight |
kg
|
47
|
Included in the box |
|
Rubber feet, drainage pipe, water union
|
Specifications | Units | I-PAC 12ALX |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
12-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
13
|
COP range |
|
13.5-5.6
|
Average COP at 50% speed |
|
9.7
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
9.5
|
COP range |
|
7.0-4.0
|
Average COP at 50% speed |
|
6.1
|
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
5.6
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
5.2
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.40-2.38
|
Maximum input current |
A
|
12.5
|
Water flow |
m³/h
|
4.0-6.0
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight/CO2 equivalent |
kg/tons
|
0.9/0.61
|
Sound level @ 10m |
dB(A)
|
21.9-32.0
|
Product size (w x d x h) |
mm
|
864 x 359 x 648
|
Weight |
kg
|
49
|
Included in the box |
|
Rubber feet, drainage pipe, water union
|
Specifications | Units | I-PAC 16ALX |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
12-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
20
|
COP range |
|
13.5-5.7
|
Average COP at 50% speed |
|
9.3
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
13.5
|
COP range |
|
7.0-4.2
|
Average COP at 50% speed |
|
6.3
|
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
7.9
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
7.4
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.57-3.21
|
Maximum input current |
A
|
19.5
|
Water flow |
m³/h
|
7.0-10.0
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight/CO2 equivalent |
kg/tons
|
1.1/0.74
|
Sound level @ 10m |
dB(A)
|
24.3-36.1
|
Product size (w x d x h) |
mm
|
954 x 359 x748
|
Weight |
kg
|
68
|
Included in the box |
|
Rubber feet, drainage pipe, water union
|
Specifications | Units | I-PAC 22ALX |
---|---|---|
Air temperature range |
°C
|
-5-43
|
Water temperature range |
°C
|
12-40
|
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity |
kW
|
25
|
COP range |
|
13.8-5.8
|
Average COP at 50% speed |
|
9.6
|
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity |
kW
|
17
|
COP range |
|
7.2-4.0
|
Average COP at 50% speed |
|
6.4
|
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity |
kW
|
9.9
|
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity |
kW
|
9.4
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kW
|
0.69-4.25
|
Maximum input current |
A
|
20
|
Water flow |
m³/h
|
10.0-12.0
|
Water connection |
"/mm
|
1½/50
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight/CO2 equivalent |
kg/tons
|
2.0/1.35
|
Sound level @ 10m |
dB(A)
|
24.9-36.7
|
Product size (w x d x h) |
mm
|
1084 x 429 x 948
|
Weight |
kg
|
90
|
Included in the box |
|
Rubber feet, drainage pipe, water union
|